8 Channel Cervical Spine Array for 7 T
Description
- phased array for cervical spine application
- 8 independent Tx/Rx channels
- sensitive area C1-C7
- single transmit (through adaptor) and pTx
- B0-field strength 7T
- anatomically shaped coil housing
- approx. housing dimensions: 52 x 49 x 17 cm3 (l/w/h)
- approx. weight: 8 kg (without adaptor)
- individual interfacing to different MR
- systems
- no medical device
A. Massire, V. Callot, CRMBM-CEMEREM, Marseille, France
Datasheet
Publications
Roussel, Y. Le Fur, M. Guye, P. Viout, J.P. Ranjeva, V. Callot: Respiratory-gated quantitative MR spectroscopy of the human spinal cord at 7 T. Magnetic Resonance in Medicine (2022)
NJ. Laines Medina, C. Gros, J. Cohen-Adad, V. Callot, A. Le Troter: 2D Multi-Class Model for Gray and White Matter Segmentation of the cervical spinal cord at 7T. arXiv (preprint 2021) View publication
Callot, A. Massire, M. Guye, S. Attarian, A. Verschueren: Visualization of gray matter atrophy and anterior corticospinal tract signal hyperintensity in Amyotrophic Lateral Sclerosis using 7T MRI. Neurology (2021) 96(23):1094-95
Lévy, PH. Roche, M. Guye, V. Callot: Feasibility of human spinal cord perfusion mapping using Dynamic Susceptibility Contrast imaging at 7T: preliminary results and identified guidelines. Magn Reson Med (2021) 85(3):1183-1194, doi: 10.1002/mrm.28559
A. Massire, H. Rasoanandrianina, M. Guye, V. Callot: Anterior fissure, central canal, posterior septum and more: new insights into the cervical spinal cord gray and white matter regional organization using T1 mapping at 7T. Neuroimage (2020) 205: 116275. View publication
Lévy S, Rapacchi S, Massire A, et al.: Intravoxel Incoherent Motion at 7 Tesla to quantify human spinal cord perfusion: Limitations and promises. Magnetic Resonance in Medicine (2020) DOI: 10.1002/mrm.28195
A. Massire et al.: Feasibility of Single-Shot Multi-Level Multi-Angle Diffusion Tensor Imaging of the Human Cervical Spinal Cord at 7T.
Magnetic Resonance in Medicine (2018) DOI: 10.1002/mrm.27087
Massire et al.: MR imaging of the cervical spinal cord at 7T: a multiparametric portfolio.
MAGNETOM Flash, 70, 112 – 119 (2018)
A. Massire et al.: Feasibility of Single-Shot Multi-Level Multi-Angle Diffusion Tensor Imaging of the Human Cervical Spinal Cord at 7T. Magnetic Resonance in Medicine 00:00–00 (2018) and
A. Massire et al.: High-resolution multi-parametric quantitative magnetic resonance imaging of the human cervical spinal cord at 7T.
NeuroImage, doi: 10.1016/j.neuroimage.2016.08.055 (2016)
all with RAPID Biomedical coil # P-H08L-070-01608-001 V01
Please ask for further suggestions of publications.