8 Channel Cervical Spine Array for 7 T

Description

  • phased array for cervical spine application
  • 8 independent Tx/Rx channels
  • sensitive area C1-C7
  • single transmit (through adaptor) and pTx
  • B0-field strength 7T
  •  anatomically shaped coil housing
  • approx. housing dimensions: 52 x 49 x 17 cm3 (l/w/h)
  •  approx. weight: 8 kg (without adaptor)
  • individual interfacing to different MR
  • systems
  • no medical device

 


Image Courtesy:

A. Massire, V. Callot, CRMBM-CEMEREM, Marseille, France  

Datasheet

Download information about 8 Channel Cervical Spine Array for 7 T as PDF .

Publications

Roussel, Y. Le Fur, M. Guye, P. Viout, J.P. Ranjeva, V. Callot: Respiratory-gated quantitative MR spectroscopy of the human spinal cord at 7 T. Magnetic Resonance in Medicine (2022) 

NJ. Laines Medina, C. Gros, J. Cohen-Adad, V. Callot, A. Le Troter: 2D Multi-Class Model for Gray and White Matter Segmentation of the cervical spinal cord at 7T. arXiv (preprint 2021) View publication

Callot, A. Massire, M. Guye, S. Attarian, A. Verschueren: Visualization of gray matter atrophy and anterior corticospinal tract signal hyperintensity in Amyotrophic Lateral Sclerosis using 7T MRI. Neurology (2021) 96(23):1094-95

Lévy, PH. Roche, M. Guye, V. Callot: Feasibility of human spinal cord perfusion mapping using Dynamic Susceptibility Contrast imaging at 7T: preliminary results and identified guidelines. Magn Reson Med (2021) 85(3):1183-1194, doi: 10.1002/mrm.28559

A. Massire, H. Rasoanandrianina, M. Guye, V. Callot: Anterior fissure, central canal, posterior septum and more: new insights into the cervical spinal cord gray and white matter regional organization using T1 mapping at 7T. Neuroimage (2020) 205: 116275. View publication

Lévy S, Rapacchi S, Massire A, et al.: Intravoxel Incoherent Motion at 7 Tesla to quantify human spinal cord perfusion: Limitations and promises. Magnetic Resonance in Medicine (2020) DOI: 10.1002/mrm.28195

A. Massire et al.: Feasibility of Single-Shot Multi-Level Multi-Angle Diffusion Tensor Imaging of the Human Cervical Spinal Cord at 7T.
Magnetic Resonance in Medicine (2018) DOI: 10.1002/mrm.27087

Massire et al.: MR imaging of the cervical spinal cord at 7T: a multiparametric portfolio.
MAGNETOM Flash, 70, 112 – 119 (2018)

A. Massire et al.: Feasibility of Single-Shot Multi-Level Multi-Angle Diffusion Tensor Imaging of the Human Cervical Spinal Cord at 7T. Magnetic Resonance in Medicine 00:00–00 (2018)  and

A. Massire et al.:  High-resolution multi-parametric quantitative magnetic resonance imaging of the human cervical spinal cord at 7T.
NeuroImage, doi: 10.1016/j.neuroimage.2016.08.055 (2016)
all with RAPID Biomedical coil # P-H08L-070-01608-001 V01

Please ask for further suggestions of publications.

 

RAPID Biomedical GmbH
Kettelerstrasse 3-11
97222 Rimpar
Germany

Phone: + 49 (0) 9365 / 88 26 – 0
Fax: + 49 (0) 9365 / 88 26 – 99

info@rapidbiomed.de
www.rapidbiomed.de

For US, Canada and South America please contact our sister company RAPID MR International.
Find information about our strategic partner Fastron Group.

Source: https://www.rapidbiomed.de/product/8-channel-cervical-spine-array-for-7-t/

The owner of this website has made a commitment to accessibility and inclusion, please report any problems that you encounter using the contact form on this website. This site uses the WP ADA Compliance Check plugin to enhance accessibility.